{"$schema":"https://bim.house/spec/v1.json","audit":{"checks":{"building_coverage":{"built_area_m2":220.45114,"coverage_pct":27.556392499999998,"limit_pct":70.0,"pass":true,"site_area_m2":800.0},"daylight":{"actual_ratio":0.2740338462578525,"floor_area_m2":199.98784,"pass":true,"window_area_m2":54.803437},"floor_area_ratio":{"far_pct":24.99848,"gross_floor_m2":199.98784,"limit_pct":200.0,"pass":true},"north_slope":{"max_height_mm":4020,"pass":true},"road_slope":{"max_height_mm":4020,"pass":true},"ventilation":{"actual_ratio":0.13701692312892624,"pass":true}},"engine":"houki v1","overall_pass":true},"elements":[{"cls":"IFCSLAB","d":11180,"descr":"鉄筋コンクリート (concrete) 布基礎 + ベタ基礎 t150 / Fc24・D13@200","h":450,"id":"e1","label":"基礎スラブ (布基礎)","rotation":0.0,"shape":"box","w":17888,"x":8944,"y":5590,"z":-450},{"cls":"IFCSLAB","d":11180,"descr":"構造用合板 t24 (wood) 剛床 + 製材根太 @303 / 床下 GW断熱","h":120,"id":"e2","label":"1F 床スラブ","rotation":0.0,"shape":"box","w":17888,"x":8944,"y":5590,"z":0},{"cls":"IFCWALL","d":150,"descr":"木製 軸組外壁 (wood) + 高性能GW t105 充填 + 付加断熱 t100 + 通気層 + 窯業系サイディング / 準耐火・寒冷地外皮強化","h":2900,"id":"e3","label":"1F 南面 外壁","rotation":0.0,"shape":"box","w":17888,"x":8944,"y":5590,"z":0},{"cls":"IFCWALL","d":150,"descr":"木製 軸組外壁 (wood) + 高性能GW t105 充填 + 付加断熱 t100 + 通気層 + 窯業系サイディング / 準耐火・寒冷地外皮強化","h":2900,"id":"e4","label":"1F 北面 外壁","rotation":0.0,"shape":"box","w":17888,"x":8944,"y":16620,"z":0},{"cls":"IFCWALL","d":11180,"descr":"木製 軸組外壁 (wood) + 高性能GW t105 充填 + 付加断熱 t100 + 通気層 + 窯業系サイディング / 準耐火・寒冷地外皮強化","h":2900,"id":"e5","label":"1F 東面 外壁","rotation":0.0,"shape":"box","w":150,"x":26682,"y":5590,"z":0},{"cls":"IFCWALL","d":11180,"descr":"木製 軸組外壁 (wood) + 高性能GW t105 充填 + 付加断熱 t100 + 通気層 + 窯業系サイディング / 準耐火・寒冷地外皮強化","h":2900,"id":"e6","label":"1F 西面 外壁","rotation":0.0,"shape":"box","w":150,"x":8944,"y":5590,"z":0},{"cls":"IFCWINDOW","d":150,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":1927,"id":"e7","label":"1F 南窓1 (掃出し)","rotation":0.0,"shape":"box","w":7870,"x":9838,"y":5590,"z":100},{"cls":"IFCWINDOW","d":150,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":1681,"id":"e8","label":"1F 南窓2 (大)","rotation":0.0,"shape":"box","w":7870,"x":18066,"y":5590,"z":550},{"cls":"IFCWINDOW","d":6708,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":1640,"id":"e9","label":"1F 西窓 (大)","rotation":0.0,"shape":"box","w":150,"x":8944,"y":6708,"z":200},{"cls":"IFCWINDOW","d":4472,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":1312,"id":"e10","label":"1F 東窓","rotation":0.0,"shape":"box","w":150,"x":26682,"y":11180,"z":650},{"cls":"IFCWINDOW","d":150,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":984,"id":"e11","label":"1F 北窓","rotation":0.0,"shape":"box","w":6439,"x":16099,"y":16620,"z":1000},{"cls":"IFCWALL","d":105,"descr":"構造用合板 耐力壁 (wood) + 製材軸組 + 高性能GW t105 充填断熱 / 壁倍率2.5・準耐火","h":2900,"id":"e12","label":"耐力壁 (東西間仕切り)","rotation":0.0,"shape":"box","w":17588,"x":9094,"y":11180,"z":0},{"cls":"IFCWALL","d":10880,"descr":"構造用合板 耐力壁 (wood) + 製材軸組 + 高性能GW t105 充填断熱 / 壁倍率2.5・準耐火","h":2900,"id":"e13","label":"耐力壁 (南北間仕切り)","rotation":0.0,"shape":"box","w":105,"x":18245,"y":5740,"z":0},{"cls":"IFCDOOR","d":150,"descr":"断熱玄関ドア 木製芯 (wood) / K2 防犯・採風機構","h":2200,"id":"e14","label":"玄関ドア (南東)","rotation":0.0,"shape":"box","w":1000,"x":22181,"y":5590,"z":0},{"cls":"IFCSLAB","d":1300,"descr":"屋外ウッドデッキ ハードウッド (wood) / 根太 + 束","h":180,"id":"e15","label":"南デッキ (縁側)","rotation":0.0,"shape":"box","w":15741,"x":10017,"y":4290,"z":0},{"cls":"IFCROOF","d":12980,"descr":"ガルバリウム鋼板 (steel) 立平葺き t0.4 + 雪止め金物 + 通気層 + GW t300 / 不燃・耐積雪・寒冷地仕様","h":220,"id":"e16","label":"大屋根 (軒の出 900)","rotation":0.0,"shape":"box","w":19688,"x":8044,"y":4690,"z":2900},{"cls":"IFCWALL","d":3896,"descr":"製材軸組 (wood) + PB t12.5 両面仕上 / 非耐力 間仕切","h":2900,"id":"e17","label":"1F 間仕切り (寝室)","rotation":0.0,"shape":"box","w":105,"x":21823,"y":12074,"z":0},{"cls":"IFCDOOR","d":105,"descr":"断熱玄関ドア 木製芯 (wood) / K2 防犯・採風機構","h":2000,"id":"e18","label":"1F 室内ドア (寝室)","rotation":0.0,"shape":"box","w":780,"x":21928,"y":12074,"z":0},{"cls":"IFCFURNISHINGELEMENT","d":600,"descr":"家具・什器 (可動)","h":1900,"id":"e19","label":"1F クローゼット","rotation":0.0,"shape":"box","w":1600,"x":22223,"y":15970,"z":135},{"cls":"IFCWALL","d":105,"descr":"製材軸組 (wood) + PB t12.5 両面仕上 / 非耐力 間仕切","h":2900,"id":"e20","label":"間仕切り (水回り廊下)","rotation":0.0,"shape":"box","w":9688,"x":9094,"y":13639,"z":0},{"cls":"IFCWALL","d":2757,"descr":"製材軸組 (wood) + PB t12.5 両面仕上 / 非耐力 間仕切","h":2900,"id":"e21","label":"間仕切り (浴室/洗面)","rotation":0.0,"shape":"box","w":105,"x":13237,"y":13863,"z":0},{"cls":"IFCWALL","d":2757,"descr":"製材軸組 (wood) + PB t12.5 両面仕上 / 非耐力 間仕切","h":2900,"id":"e22","label":"間仕切り (洗面/トイレ)","rotation":0.0,"shape":"box","w":105,"x":16099,"y":13863,"z":0},{"cls":"IFCDOOR","d":105,"descr":"断熱玄関ドア 木製芯 (wood) / K2 防犯・採風機構","h":2000,"id":"e23","label":"室内ドア (洗面)","rotation":0.0,"shape":"box","w":730,"x":14310,"y":13639,"z":0},{"cls":"IFCWALL","d":1677,"descr":"製材軸組 (wood) + PB t12.5 両面仕上 / 非耐力 間仕切","h":2900,"id":"e24","label":"間仕切り (玄関ホール)","rotation":0.0,"shape":"box","w":105,"x":20034,"y":5740,"z":0},{"cls":"IFCWALL","d":105,"descr":"製材軸組 (wood) + PB t12.5 両面仕上 / 非耐力 間仕切","h":2900,"id":"e25","label":"間仕切り (キッチン背面)","rotation":0.0,"shape":"box","w":6439,"x":18603,"y":8273,"z":0},{"cls":"IFCWINDOW","d":150,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":369,"id":"e26","label":"1F 浴室窓 (北高窓)","rotation":0.0,"shape":"box","w":1431,"x":10732,"y":16620,"z":2150},{"cls":"IFCWINDOW","d":150,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":369,"id":"e27","label":"1F 洗面窓 (北高窓)","rotation":0.0,"shape":"box","w":1431,"x":13594,"y":16620,"z":2150},{"cls":"IFCWINDOW","d":150,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":369,"id":"e28","label":"1F トイレ窓 (北高窓)","rotation":0.0,"shape":"box","w":1431,"x":16456,"y":16620,"z":2150},{"cls":"IFCWINDOW","d":900,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":82,"id":"e29","label":"トップライト (南)","rotation":0.0,"shape":"box","w":900,"x":13952,"y":9503,"z":3130},{"cls":"IFCWINDOW","d":900,"descr":"Low-E トリプルガラス アルゴン封入 + 樹脂サッシ (glass) / U=1.1 W/m²K・寒冷地仕様","h":82,"id":"e30","label":"トップライト (東)","rotation":0.0,"shape":"box","w":900,"x":20034,"y":9503,"z":3130},{"cls":"IFCENERGYCONVERSIONDEVICE","d":2012,"descr":"auto BIM (MCP create_house)","h":80,"id":"e31","label":"太陽光パネル (4kW)","rotation":0.0,"shape":"box","w":7512,"x":10375,"y":6260,"z":3130},{"cls":"IFCFLOWSTORAGEDEVICE","d":900,"descr":"auto BIM (MCP create_house)","h":1600,"id":"e32","label":"雨水タンク (200L)","rotation":0.0,"shape":"box","w":900,"x":7844,"y":8049,"z":0},{"cls":"IFCSLAB","d":2906,"descr":"構造用合板 t24 (wood) 剛床 + 製材根太 @303 / 床下 GW断熱","h":100,"id":"e33","label":"ロフト床 (小屋裏収納)","rotation":0.0,"shape":"box","w":17388,"x":9194,"y":9727,"z":1700},{"cls":"IFCSTAIR","d":1100,"descr":"木製 直階段 (wood) 蹴上 200 踏面 230 + 手すり / 14段","h":1700,"id":"e34","label":"ロフトはしご","rotation":0.0,"shape":"box","w":500,"x":17888,"y":8527,"z":0},{"cls":"IFCCOVERING","d":11060,"descr":"オーク無垢フローリング t15 直貼り / 仕上げ床","h":15,"id":"e35","label":"フローリング (仕上げ床)","rotation":0.0,"shape":"box","w":17768,"x":9004,"y":5650,"z":120},{"cls":"IFCFURNISHINGELEMENT","d":850,"descr":"木フレーム (wood) + ファブリック張り","h":720,"id":"e36","label":"ソファ (3人掛け)","rotation":0.0,"shape":"box","w":2000,"x":10732,"y":7378,"z":135},{"cls":"IFCFURNISHINGELEMENT","d":550,"descr":"木製家具 (wood)","h":380,"id":"e37","label":"ローテーブル","rotation":0.0,"shape":"box","w":1100,"x":11448,"y":6372,"z":135},{"cls":"IFCFURNISHINGELEMENT","d":850,"descr":"木製家具 (wood)","h":720,"id":"e38","label":"ダイニングテーブル+椅子","rotation":0.0,"shape":"box","w":1500,"x":18245,"y":7378,"z":135},{"cls":"IFCFURNISHINGELEMENT","d":650,"descr":"システムキッチン ステンレス天板 (steel) + 木質扉","h":850,"id":"e39","label":"システムキッチン","rotation":0.0,"shape":"box","w":2550,"x":17888,"y":6037,"z":135},{"cls":"IFCFURNISHINGELEMENT","d":400,"descr":"木製家具 (wood)","h":450,"id":"e40","label":"TV ボード","rotation":0.0,"shape":"box","w":1800,"x":10732,"y":11180,"z":135},{"cls":"IFCSANITARYTERMINAL","d":1500,"descr":"ユニットバス 1616 サイズ / FRP 防水パン","h":500,"id":"e41","label":"ユニットバス","rotation":0.0,"shape":"box","w":1600,"x":9144,"y":14310,"z":135},{"cls":"IFCSANITARYTERMINAL","d":520,"descr":"洗面化粧台 三面鏡 + ボウル一体カウンター","h":800,"id":"e42","label":"洗面化粧台","rotation":0.0,"shape":"box","w":750,"x":14310,"y":15428,"z":135},{"cls":"IFCSANITARYTERMINAL","d":700,"descr":"温水洗浄便座 + 手洗い / 節水型","h":420,"id":"e43","label":"トイレ (便器)","rotation":0.0,"shape":"box","w":450,"x":17172,"y":15652,"z":135},{"cls":"IFCCOVERING","d":1100,"descr":"ケイカル板 t12 + 磁器質タイル t10 (tile) / 可燃物床防護・前方450 確保","h":75,"id":"e44","label":"炉台 (薪ストーブ床防護)","rotation":0.0,"shape":"box","w":1300,"x":15383,"y":6484,"z":120},{"cls":"IFCFLOWTERMINAL","d":550,"descr":"鋳鉄製 薪ストーブ (steel) 8kW級 / 炉壁・側方450/後方300 離隔確保","h":950,"id":"e45","label":"薪ストーブ","rotation":0.0,"shape":"box","w":650,"x":15708,"y":6759,"z":195},{"cls":"IFCCHIMNEY","d":200,"descr":"ステンレス断熱二重煙突 φ200 (steel) / 屋根貫通部 メガネ石・可燃物離隔150・屋外立上り 支持金物","h":2875,"id":"e46","label":"煙突 (断熱二重煙突)","rotation":0.0,"shape":"cylinder","w":200,"x":15933,"y":6934,"z":1145},{"cls":"IFCFURNISHINGELEMENT","d":1800,"descr":"杉材 薪棚 (wood) 約1.5㎥ / 屋外・雨掛り屋根付き","h":1400,"id":"e47","label":"薪棚 (屋外)","rotation":0.0,"shape":"box","w":450,"x":27132,"y":11739,"z":0},{"cls":"IFCFURNISHINGELEMENT","d":600,"descr":"木製家具 (wood)","h":720,"id":"e48","label":"書斎デスク+チェア","rotation":0.0,"shape":"box","w":1200,"x":21823,"y":12074,"z":135},{"cls":"IFCFURNISHINGELEMENT","d":1500,"descr":"木製家具 (wood)","h":1800,"id":"e49","label":"書斎本棚","rotation":0.0,"shape":"box","w":350,"x":26282,"y":11403,"z":135}],"project":{"address":"北海道上川郡上川町","annual_precipitation_mm":920,"annual_temperature":{"avg_c":6.5,"max_c":28,"min_c":-25},"applicant":{"_estimated":true,"_note":"建築主=作成者本人。実名は確認申請時に確定 (is_owner=true)","is_owner":true,"name":null,"owner_type":"施主本人 (ユーザー作成スタディ)"},"barrier_free":{"_note":"建基法・高齢者等配慮対策 標準寸法。実設計で個別確認","min_corridor_mm":780,"min_door_mm":750,"step_free":"要計画"},"climate_zone_meti":1,"construction_jpy":73024000,"construction_jpy_estimated":true,"contractor":{"_note":"施工者は着工契約時に確定 (建設業法 19 条)。保証年数は宅建業法 + 住宅品確法 標準値","office_name":null,"registration":null,"warranty_years_construction_typical":10,"warranty_years_structure_typical":30,"warranty_years_water_leak_typical":10},"designer":{"_note":"office_registration / kenchikushi_number は登録建築士事務所が確認申請時に記入","designer_kenchikushi_class":null,"designer_kenchikushi_number":null,"designer_name":"濱田優貴","designer_role":"意匠・構造・設備 統合設計","email":"mail@yukihamada.jp","kanri_kenchikushi_name":null,"kanri_kenchikushi_number":null,"office_address":"〒102-0074 東京都千代田区九段南 1-5-6 りそな九段ビル 5F","office_name":"株式会社イネブラ","office_registration":null},"drainage":{"_estimated":true,"_note":"排水方式・放流先は確認申請時に現地確認","discharge_to":null,"method":"要現地確認 (公共下水道接続 or 浄化槽)"},"fetched_at":"2026-10-29","fire_district":null,"grades":{"_disclaimer":"認定取得には別途認定機関への申請が必要","bels_grade_target":"★★★","casbee_rating_target":"B+","chouki_yuryo_housing":{"_note":"実認定は住宅性能評価機関による (例: ハウスプラス、日本ERI)。本JSONは目標値","eligible_by_size":false,"status":"target"},"earthquake_resistance_grade_target":2,"energy_consumption_grade_target":5,"low_carbon_housing":{"co2_reduction_pct_target":20,"status":"target"},"sick_house_grade_target":3},"ground_acceleration_design_gal":250.0,"ground_investigation":{"_estimated":true,"_note":"本 N 値は地域標準からの推定。着工前に地盤調査を実施し確定する","method":"要地盤調査 (SWS / ボーリング)","n_value_avg":12.0},"lat":null,"license":"MIT","license_note":"BIM データ・図面・コスト・居住後 evaluation を MIT ライセンスで公開 (https://github.com/yukihamada/tsugi)","lng":null,"lot_d_m":22.360679774997894,"lot_w_m":35.77708763999664,"maintenance_schedule":{"10yr":["外壁再塗装 (ガルバ/木材保護塗装)","防水層点検"],"15yr":["屋根材点検 (ガルバ留め直し)","給湯機器更新検討"],"25yr":["屋根葺き替え (ガルバ系)","断熱層点検"],"30yr":["躯体点検 (構造保証期限)","設備機器一斉更新"],"50yr":["大規模リノベーション or 解体判断"],"5yr":["シーリング再施工 (開口部周り)","塗装劣化チェック"],"_note":"本表は構造種別と地域 (積雪・寒冷地) から自動推定。実 maintenance は施工者・メーカー仕様書を優先","_structure_class":"一般木造","annual":["換気フィルター清掃","給排水管 目視点検","外壁目視・雨樋清掃","雪止め金物点検","煙突清掃 (薪ストーブ)"]},"mep":{"_estimated":true,"_note":"設備計画は実施設計で確定","drain_method":"要計画 (公共下水 or 浄化槽)","heat_method":"要計画","vent_method":"24 時間換気 (建基法 シックハウス対策 令 20 条の 8)","water_method":"要計画 (公共水道 or 井戸)"},"n_elements":49,"name":"上川町の家","permit_classification":"建基法 6 条 (小規模 — 確認申請要、号区分は要詳細判定)","permit_documents_checklist":["確認申請書","建築計画概要書","配置図 (1:200)","各階平面図 (1:100)","立面図 4 面 (1:100)","断面図 2 面 (1:100)","構造図 (伏図・軸組・基礎)","構造計算書","設備図 (給排水・電気・換気)","シックハウス対策表","省エネ計算書 (UA 値)","防火区画図","避難経路図","採光換気計算表","面積表 (建ぺい・容積)","工事監理者選任届","建築士事務所登録写"],"proposed_floors":1,"proposed_gross_m2":200.0,"proposed_structure":"木造軸組 + トリプルガラス + 付加断熱","road_access":{"_estimated":true,"compliance":"道路幅員 未登録 — 推定 4.0m、要現地確認","road_setback_required_m":0.0,"road_type":"未登録 — 要現地確認 (北海道、町道想定)","road_width_m":4.0},"road_width_m":null,"rooms":[{"_source":"proposed_rooms サマリーから自動分解","id":"r1","name":"3LDK"},{"_source":"proposed_rooms サマリーから自動分解","id":"r2","name":"薪ストーブ"},{"_source":"proposed_rooms サマリーから自動分解","id":"r3","name":"書斎"}],"seismic_zone_factor":0.9,"site_area_m2":800.0,"slug":"u-house-hc7cm7fv","snow_depth_design_m":1.3,"snow_load_kn_m2":1.8,"supervisor":{"_note":"確認申請時に登録建築士が工事監理者に就任 (建築士法 22 条の 3)","supervisor_name":"濱田優貴 (設計監理)"},"tax_treatment":"10% 税込 (本体工事費)","wind_speed_design_m_s":34,"wind_zone":2,"zoning":""},"spec_version":"1.0.0"}