{"citations":[{"law":"建築基準法 第 28 条 1 項","title":"居室の採光"},{"law":"建築基準法 第 28 条 2 項","title":"居室の換気"},{"law":"建築基準法施行令 第 19 条","title":"採光及び換気を必要とする居室"},{"law":"建築基準法施行令 第 20 条","title":"有効面積の算定方法 (D/H 補正係数)"},{"law":"国土交通省告示 第 1116 号 (平 7)","title":"居室の採光に関する技術的基準"},{"law":"建築基準法 第 28 条の 2","title":"シックハウス対策 (居室の換気設備)"},{"law":"建築基準法施行令 第 20 条の 5","title":"居室の機械換気設備の構造"}],"daylight_formula":"A = 10 × D/H − 1.0 (商業・工業地域)","generated_at":{"iso8601_utc":"2026-08-17T18:19:35Z","wareki":"令和 8 年 8 月 17 日"},"ok":true,"rooms":[{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"平屋(矩形)","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"雨水利用とPVのオフグリッド志向・平屋","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"高気密高断熱施工(Ua0.47基準)","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"屋上太陽光パネル","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"蓄電池","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"雨水タンク埋設","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"吹抜なしの平屋で断熱性能最大化","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"南面を大きく開口し自然採光を確保","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}},{"area_m2":0.0,"daylight":{"actual_ratio":0.0,"correction_factor_d_h":1.0,"effective_ratio":0.0,"effective_window_area_m2":0.0,"pass":false,"required_ratio":0.14285714285714285,"window_area_m2":0.0},"name":"オフグリッド対応の自立型エネルギーシステム","ventilation":{"actual_ratio":0.0,"effective_open_area_m2":0.0,"pass":false,"required_ratio":0.05}}],"schema":"saiko-kanki/v1","site":{"address":"鹿児島県霧島市","land_area_m2":95.0,"zoning":"近隣商業地域"},"slug":"u-pv-5efq3eu5","summary":{"daylight_pass":0,"daylight_pass_all":false,"overall_pass":false,"total_rooms":9,"ventilation_pass":0,"ventilation_pass_all":false},"title":"鹿児島・雨水利用とPVのオフグリッド志向"}